SOLARPANEL FLUID 100 is biodegradable concentrated fluid based on propylene glycol for the heat transfer and protection from the freezing and corrosion. It is free of harmful amines, phosphates and nitrates.
SOLARPANEL FLUID 100 is used in solar and central heating systems, and for technological cooling / heating in the food industry (brewery, juice factories, dairies, cold storage, butchers etc). Replacement period is 5 years. Concentrations below 25% and above 75% are not recommended. Shelf life in the system is 10 years.
Needs to be deluted with demineralized water in a relations from the table.
| Solarpanel fluid 100 (vol) | Demineralized water (vol) | Freezing point (°C) |
|---|---|---|
| 2 (67%) | 1 (33%) | -57 |
| 1 (50%) | 1 (50%) | -33 |
| 1 (45%) | 1,2 (55%) | -25 |
| 1 (40%) | 1,5 (60%) | -20 |
| 1 (33%) | 2 (67%) | -15 |
| Characteristics | Units | Typical values | Test methods |
|---|---|---|---|
| Density on 20°C | g/cm3 | 1,03-1,05 | SRPS EN ISO 3675 |
| Color | - | Green | Visually |
| Boiling point, min | °C | 188 | SRPS H.Z8.058 |
| Corrosion of metals in a glass apparatus | mg | It satisfies | SRPS H.Z8.056 |
| pH - value, diluted with water 1:1 | - | 7,5-9,0 | SRPS H.Z8.052 |
| Freezing point, diluted with water 1:1, min | °C | -33 | SRPS H.Z8.053 |
SOLARPANEL FLUID 100 should be stored in their original packaging protected from the direct influence of the atmosphere.
SRPS H.Z2.010, tip II; ASTM D 3306;
10L, 20L, 220kg, 1000L
Safety data sheet SOLAR PANEL FLUID 20
Safety data sheet SOLAR PANEL FLUID 40
Safety data sheet SOLAR PANEL FLUID M 40
Safety data sheet SOLAR PANEL FLUID 100